Sample cooler SC32F -SC1232F (with funnel)
ADCA sample coolers SC32F - SC132F are specially designed to cool steam boiler water samples for analysis. These sample coolers prevent the formation of re-evaporation of samples obtained from hot liquids under pressure, which can be dangerous for the integrity of the operator performing the operation and will result in an incorrect water sample. This device can be used for boiler water analysis as well as other types of sampling or cooling applications compatible with the materials of construction.
- Corrosion resistant body and internal parts.
- Self-draining sample (top inlet, bottom outlet).
- Sample inlet valve.
- Cooling water inlet valve.
- Temperature indicator.
- Compression fittings.
- Bolted top plate.
- Different sizes and connection materials on request.
- Steam boilers and hot water systems
- SC32F/SS and SC132F/SS - stainless steel body and coil.
- Cooling water inlet 1/2", outlet 3/4" (ISO 7 Rp or NPT)
- Sampling tube inlet/outlet: 8 mm O/D
- Vertical installation.
- See IMI - Installation and Maintenance Instructions.
- The cooling water must be at maximum flow rate before opening or closing the sample inlet valve to avoid the risk of scalding.
- The sample valve must also be closed before opening the cooling water valve.
- The sampling coil must always be completely submerged in water.
- From 30 to 60 kg/h of sampling liquid at ≈30 ºC with 1 m³/ cooling water inlet at 15 ºC (boilers up to 20 bar - 220 ºC), for other pressures, temperatures and/or certified values, consult the manufacturer.